Product Tag: ES-Link

YaMoRC products with ES-Link capabilities

YD7403

YD7403

The power-house of the YD7x family,

It presents:

  • Universal 3.5 Amp booster.
  • Fully galvanically isolated on all, defacto industry standard inputs:
    – LocoNet – B
    – Roco B-BUS
    – DCC-CDE
    – Track Sniffer
  • Automatic input selection
  • LED indication of currently active input
  • Local GO / STOP button to start/stop the booster, or reset in case of local short circuit
  • Follows input RailCom Cut-Out to it’s output
  • ES-PGM-LINK for easy configuration

Power:

  • Input 15-19 V DC
  • Output 3.5 A peak current, 2.75 A continuous.
  • Short circuit protected
  • Automatic short-report over LocoNet, CDE channel or BBus interface.
  • H-Bridge Temperature measurement
  • Track-Current measurement
  • Input- and Track Voltage measurement
YD6901ES-LINK

YD6901ES-LINK

The actual adapter that creates the ES/IO – LINK between modules

YD8116

YD8116

The YaMoRC solution for switching and signaling: our 16-fold signal/switching decoder.

It presents the following features:

  • Sixteen independent 2.5Amp MOSFET outputs
  • Max 5 Amp combined current
  • Very simple basic-setup (base address), by pressing the programming button and switching the desired turnout address
  • No complicated CV settings.
  • Clear-text configuration based upon our new ES-Link technology.
    With our YD9101-Config or YD7100-Command, configuration can be done via built-in web interface: No need for PC-software or Phone/Tablet Apps!.
    – or –
    when using the classic Windows PC interface, the YD9100 config-USB-stick as well as our YD6016LN can provide the configuration.
  • All of the 16 outputs are freely configurable from 16x simple on-off to complex and elaborate signals with up to 8 LEDs/lamps
  • Each defined device (signal, switch, turnout) can have its own address
  • Devices can be operated by the new DCCext standard or conventional turnout DCC-commands (throw/close)
  • Numerous predefined signal definitions for Dutch, German (H/V, Ks and Form) British and Swiss prototypical signals
  • Signals can include fading (Bulbs emulated in case of LEDs) dark-phase inclusion, black-out based on previous signals state
  • Outputs can be time-limited e.g. for light coil-motors
  • Settable night-dimming for the complete decoder, with configurable address / decoder
  • Very suitable for motorized point motors.
  • Not suitable for solenoid point motors. For these motors, use our YD8008/YD8044.
  • For two-wire motorized point motors, like Conrad; Hoffmann; Tillig; etc. adapter YD6940 should be used.

How to configure the YD8116 with Viessmann signals and ECoS

YD6016LN-RC

YD6016LN-RC

Delay reason: Our production capacity is insufficient to produce it at the moment

The RailCom enabled feedback module.

It presents:

  • 16 independant local RailCom detectors
  • 1 general purpose global detector on Track-Output
  • For non-RailCom equiped locos or cars, the module also provides Current Sensing on each input.
  • 3mA currentsensitivity
  • ES-IN-Link for direct connection of additional YD6016ES modules
  • ES-IN-Link connection to YD9101 for web-based configuration
  • RailCom Channel 1 and Channel 2 address detection per channel
  • RailCom POM-read on all channels
  • RailCom QoS and Acutal Speed, as well as Container data
  • USB connection with two Virtual COM ports for YD.Command and LocoNet protocols
  • Using USB-LocoNet, the module presents all its inputs, including connected YD6061ES inputs as standalone LocoNet system
  • Every input configurable for feedback and block-address
  • Powerful 32 bit ARM Processor
  • Power supply directly from Track-Input
YD8008

YD8008

Specially designed to cope with, high-current, solenoid point-motors, the YD8008 is our 8-fold solenoid decoder with intelligent CDU.

It presents the following features:

  • Eight independent 9.5Amp solenoid outputs
  • Smart, 9400 uF CDU, monitoring charge levels for safe and powerful switching
  • Only 380 mA power consumption during charging
  • Very simple basic-setup (base address), by pressing the programming button and switching the desired turnout address
  • No complicated CV settings.
  • Clear-text configuration based upon our new ES-Link technology.
    With our YD9101-Config or YD7100-Command, configuration can be done via built-in web interface. No need for PC-software or Phone/Tablet Apps !
    – or –
    when using the classic Windows PC interface, the YD9100 config-USB-stick as well as our YD6016LN can provide the configuration.
  • Eight address to output mappings, each mapping can a free choice address which can switch any and every output
  • Sequential output activation based upon pulse time and CDU charge level.
  • CDU startup delay adjustable to prevent tripping short circuit protection in boosters
  • Very modest power supply requirements. Even for SEEP/Gaugemaster motors a 15V/500mA wall wart is more than enough.
  • Not suitable for motorized point motors. For these motors, use our YD8116. This also counts for MTB point motors.
  • For two-wire solenoid motors, like Kato, adapter YD6940 should be used.
YD6016LN-GND

YD6016LN-GND

Our standard ground-input feedback module with LocoNet Interface with:

  • 16 inputs, switching against Ground ( both “C” terminals )
  • Capacitive input filter on every input, to suppress noise on long cables
  • Configurable on- and off-delay setting for each input for optimal de-bouncing of pushbuttons, switches, reed contacts
  • Every input individually configurable for various actions like feedback, turnout toggle, turnout throw, turnout close
  • Every input individually configurable for feedback- or turnout-address
  • ES-IN-Link for direct connection of up to 5 additional YD6016ES modules (effectively creating a 96 input LocoNet module)
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • ES-IN-Link connection to YD9101 for web-based configuration
  • USB connection with one Virtual COM ports for the YD.Command** protocol
  • Firmware updatable over USB
  • Power supply directly from LocoNet-T or -B ( or USB for easy configuration and updating on a PC )

**)
Disclaimer: YD.Command is the internal YaMoRC communication protocol. It is not publicly open, nor does YaMoRC supply support 3rd parties to use it. Futher can it be subject to change on demand and at will of YaMoRC, without further notice or explanation.

YD6016ES-CS

YD6016ES-CS

Our classic s88N feedback module with current sensing inputs

It presents:

  • 16 current-sensing detectors, arranged in two independent blocks of 8, each with their own Common
  • 2 Amp continuous current per detector, 8 Amps in total combined over the 16 detectors on the whole module
  • 5 Amp short duration overload (100ms) capable per detector.
  • 1-1.5mA current sensitivity
  • Capacitive input filter on every input, to suppress noise on long cables and track-sections
  • Configurable on- and off-delay setting for each input for optimal de-bouncing in case of non optimal wheel-track contact
  • ES-OUT-Link for direct connection to an ES-Link-master
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • Standard s88N connections over RJ45 connectors and ethernet patch cables
  • Firmware updatable and settings configurable over ES-Link
  • Power supply directly from ES-Link or s88 bus
YD6016ES-GND

YD6016ES-GND

Our classic s88N feedback module with ground sensitive inputs with:

  • Capacitive input filter on every input, to suppress noise on long cables
  • Configurable on- and off-delay setting for each input for optimal de-bouncing of pushbuttons, switches, reed contacts
  • ES-OUT-Link for direct connection to an ES-Link-master
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • Standard s88N connections over RJ45 connectors and ethernet patch cables
  • Firmware updatable and settings configurable over ES-Link
  • Power supply directly from ES-Link or s88 bus
YD7100

YD7100

Delay reason: The chips used for the DC-DC converters have been declared EOL. That means, the factory did not restart production after the chip-crisis. For us this means a redesign of the PCB and Software.
Please contact your dealer for alternative offers.

The smallest DCC command station on the market !

Small in form, but great in features and performance.

It presents:

  • Unique DCC signal generator:
    With priority control and interleaved packet generation.
    Changes sent  by any interface are directly being reflected to the track.
    Generates RailCom Cut-Out.
  • 3 A integrated Booster
  • Operating voltage range from  15 – 19 VDC. Giving a track-voltage of 13.8 – 17.8 Volts. That means safe for your N-scale equipment and powerful for H0.
  • Multiple Model Railroad compatible Interface Busses:
    LocoNet, the world standard set by Digitrax Inc.
    XpressNet, from the inventor of DCC: Lenz
    ES-IN-Link, the next thing after good old S88 signalling, fully compatible with s88N with our YD6902-EXT adapters.
  • USB interface for three virtual COM-ports:
    –  YD.Command **
    –  LocoNet
    –  XpressNet
    The USB connection can also be used to update the YD7100`s firmware
  • Full network capabilities:
    WiFi Access Point,
    gives direct access to smartphones, tablets and handheld controllers
    100baseT RJ45 wired network socket,
    connect and bind to your home network and reliably connect your PC software
  • By means of our YD9401 Module, provides:
    Built-in Webserver for configuring and operating the YD7100,
    with no need for PC or Phone/Tablet installed Software or Apps. Just runs from any browser !
    6 different but SIMULTANEOUS usable network protocols on WiFi and LAN:
    *    XpressNet-LAN,
    *    Z21®,
    *    LocoNet Binary,
    *    LocoNet LBServer,
    *    JMRI: WiThrottle
    *    YD.Command **
  • Booster Interface by LocoNet-B with strong, 800mA LocoNet RailSync signals
  • Powerful 1 Amp XpressNet supply
  • Roco R-BUS compatible feedbacks on XpressNet socket
  • IO-Link connector for Command Station extension like our YD7101
  • Clear LED indicators
  • Programming:
    POM write
    Service Mode ( programming track )
    ES-Link  capable modules like YD8044, YD8008, YD6016ES
  • Quality made  switch mode power supply included with choise of:
    15V fixed / 4 A
    18V fixed / 3.4A
  • Strong 32-bit ARM processor on 48 MHz

**)
Disclaimer: YD.Command is the internal YaMoRC communication protocol. It is not publicly open, nor does YaMoRC supply support 3rd parties to use it. Futher can it be subject to change on demand and at will of YaMoRC, without further notice or explanation.

YD6016LN-CS

YD6016LN-CS

Our standard current-sensing feedback module with LocoNet Interface

It presents:

  • 16 current-sensing detectors, arranged in two independent blocks of 8, each with their own Common
  • 2 Amp continuous current per detector, 8 Amps in total combined over the 16 detectors on the whole module
  • 5 Amp short duration overload (100ms) capable per detector.
  • 1-1.5mA current sensitivity
  • Capacitive input filter on every input, to suppress noise on long cables and track-sections
  • Configurable on- and off-delay setting for each input for optimal de-bouncing in case of non optimal wheel-track contact
  • Every input individually configurable for various actions like feedback, turnout toggle, turnout throw, turnout close
  • Every input individually configurable for feedback- or turnout-address
  • ES-IN-Link for direct connection of up to 5 additional YD6016ES modules (effectively creating a 96 input LocoNet module)
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • ES-IN-Link connection to YD9101 for web-based configuration
  • USB connection with one Virtual COM ports for the YD.Command** protocol
  • Firmware updatable over USB
  • Power supply directly from LocoNet-T or -B ( or USB for easy configuration and updating on a PC )

**)
Disclaimer: YD.Command is the internal YaMoRC communication protocol. It is not publicly open, nor does YaMoRC supply support 3rd parties to use it. Futher can it be subject to change on demand and at will of YaMoRC, without further notice or explanation.