Product Tag: Current Sense

The module’s sensors work according to the current sensing principle.

YD6016RB-CS

YD6016RB-CS

Our standard current-sensing feedback module with RBus / XBus Interface

It presents:

  • 16 current-sensing detectors, arranged in two independent blocks of 8, each with their own Common
  • 2 Amp continuous current per detector, 8 Amps in total combined over the 16 detectors on the whole module
  • 5 Amp short duration overload (100ms) capable per detector.
  • 1mA current sensitivity
  • Capacitive input filter on every input, to suppress noise on long cables and track-sections
  • Configurable on- and off-delay setting for each input for optimal de-bouncing in case of non optimal wheel-track contact
  • Every input individually configurable for various actions like feedback, turnout toggle, turnout throw, turnout close
  • Every input individually configurable for turnout-address
  • ES-IN-Link for direct connection of up to 4 additional YD6016ES modules (effectively creating a 80 input RBus module)
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • ES-IN-Link connection to YD9101 for web-based configuration
  • USB connection with one Virtual COM port for the YD.Command protocol
  • Firmware updatable over USB
  • Power supply directly from RBus / XBus ( or USB for easy configuration and updating on a PC )
YD6016LN-RC

YD6016LN-RC

Delay reason: Our production capacity is insufficient to produce it at the moment

The RailCom enabled feedback module.

It presents:

  • 16 independant local RailCom detectors
  • 1 general purpose global detector on Track-Output
  • For non-RailCom equiped locos or cars, the module also provides Current Sensing on each input.
  • 3mA currentsensitivity
  • ES-IN-Link for direct connection of additional YD6016ES modules
  • ES-IN-Link connection to YD9101 for web-based configuration
  • RailCom Channel 1 and Channel 2 address detection per channel
  • RailCom POM-read on all channels
  • RailCom QoS and Acutal Speed, as well as Container data
  • USB connection with two Virtual COM ports for YD.Command and LocoNet protocols
  • Using USB-LocoNet, the module presents all its inputs, including connected YD6061ES inputs as standalone LocoNet system
  • Every input configurable for feedback and block-address
  • Powerful 32 bit ARM Processor
  • Power supply directly from Track-Input
YD6016ES-CS

YD6016ES-CS

Our classic s88N feedback module with current sensing inputs

It presents:

  • 16 current-sensing detectors, arranged in two independent blocks of 8, each with their own Common
  • 2 Amp continuous current per detector, 8 Amps in total combined over the 16 detectors on the whole module
  • 5 Amp short duration overload (100ms) capable per detector.
  • 1-1.5mA current sensitivity
  • Capacitive input filter on every input, to suppress noise on long cables and track-sections
  • Configurable on- and off-delay setting for each input for optimal de-bouncing in case of non optimal wheel-track contact
  • ES-OUT-Link for direct connection to an ES-Link-master
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • Standard s88N connections over RJ45 connectors and ethernet patch cables
  • Firmware updatable and settings configurable over ES-Link
  • Power supply directly from ES-Link or s88 bus
YD6016LN-CS

YD6016LN-CS

Our standard current-sensing feedback module with LocoNet Interface

It presents:

  • 16 current-sensing detectors, arranged in two independent blocks of 8, each with their own Common
  • 2 Amp continuous current per detector, 8 Amps in total combined over the 16 detectors on the whole module
  • 5 Amp short duration overload (100ms) capable per detector.
  • 1-1.5mA current sensitivity
  • Capacitive input filter on every input, to suppress noise on long cables and track-sections
  • Configurable on- and off-delay setting for each input for optimal de-bouncing in case of non optimal wheel-track contact
  • Every input individually configurable for various actions like feedback, turnout toggle, turnout throw, turnout close
  • Every input individually configurable for feedback- or turnout-address
  • ES-IN-Link for direct connection of up to 5 additional YD6016ES modules (effectively creating a 96 input LocoNet module)
  • ES-IN-Link connection to other ES-Link enabled modules for module-configuration
  • ES-IN-Link connection to YD9101 for web-based configuration
  • USB connection with one Virtual COM ports for the YD.Command protocol
  • Firmware updatable over USB
  • Power supply directly from LocoNet-T or -B ( or USB for easy configuration and updating on a PC )